HeatLoss Pro Logo
HEATLOSS PRO
The 2026 Heat Pump Sizing Benchmark

Room-by-Room Heat Loss in 5 Minutes, Not 2 Hours.

See how HeatLoss Pro compares with Heatpunk, MCS spreadsheets and desktop CAD software. Calculate room-by-room heat loss in under 5 minutes, pay just €1.00 per job, and generate client-ready engineering reports.

5 Mins
Average Calculation Time

vs 60–90 mins in spreadsheets or traditional desktop CAD

€1.00
Pay-Per-Report Or €29.99/mo

vs €1,500 – €4,000/yr annual seat licenses

100%
Brand & Merchant Neutral

No distributor bias, specify any heat pump model

Speed & Workflow

Why HeatLoss Pro Is Faster

Traditional heat loss workflows force you to manually measure wall dimensions, look up U-values in tables, or model the building in a full CAD package. HeatLoss Pro was engineered from the ground up for lightning-quick execution.

Direct Ctrl+V Blueprint Tracing

Have a floor plan from an architect or real estate listing? Simply take a screenshot, press Ctrl+V to paste directly onto the canvas, calibrate one known dimension, and trace rooms immediately. No multi-step file uploads or CAD conversions.

Competitor time: 25 mins • HeatLoss Pro: 30 seconds

Smart Polygon Room Snapping

Drag rectangles or click custom L-shaped/angled room vertices. Our CAD engine automatically calculates wall perimeters, ceiling area, internal vs. external wall exposure, and party wall boundaries in the background while you draw.

Competitor time: 40 mins • HeatLoss Pro: 3 mins

Real-Time Reactive Math Engine

Every time you adjust a wall dimension, change insulation from solid brick to cavity with PIR, or add a radiator, the total house kW and specific W/m² update instantly. Zero progress spinners and zero wait times.

Competitors: Manual recalculate • HeatLoss Pro: Instant 60 FPS
Pricing & Transparency

Why HeatLoss Pro Costs Less

An installer or energy consultant sizing homes should not need a large annual licence. HeatLoss Pro is free to draw on, and you pay per calculation or by the month.

Best value · works offline
HeatLoss Pro

Democratic Pay-As-You-Go

€1.00 / report or €29.99/mo

Draw offline in your browser; it syncs when you're online.

  • No sign-up to start. Your projects sync to your account.
  • Only pay €1.00 when you generate a client PDF
  • 100% Brand Neutral: specify any heat pump
Enterprise CAD Tools

Hysopt / MagiCAD

€2,500+ / user / yr

Typical list price; training and support often extra.

  • Usually annual licences
  • Requires Windows CAD workstation
  • Takes time to learn
Traditional engineering firms only
Free Supplier Tools

Heatpunk (Midsummer)

Free to use

Made by Midsummer, a heating and solar supplier.

  • Built around the UK MCS process
  • Cloud-based, account required
  • No pasted floor plan tracing in the same way
Good for UK MCS designs
Training Network

Heat Geek App

£350 – £1,500+ course/network

Comes with its training courses and installer network.

  • Requires paid course or installer accreditation
  • Cloud-only portal: requires internet & login
  • No instant Ctrl+V canvas tracing
For trained network installers

Heatpunk alternative

Heatpunk is a free heat loss tool from Midsummer, built around the UK MCS process. If you are a UK installer producing MCS paperwork and are happy working in an online account, it is a sensible choice.

HeatLoss Pro fits when you want to trace a pasted floor plan room by room, design outside the UK with EN 12831 and your own design temperature, or check radiators, underfloor loops and pipework in the same drawing, paying only for the jobs you report.

Looking for the Heatpunk login? It is on Heatpunk's own website; HeatLoss Pro is a separate tool.

A cheap check before you pay for a full design

A heat loss report from an engineer or an online service is usually a one-off fee of a hundred euros or more, and design software is mostly sold as a yearly subscription. That makes sense for a full design, but not for a first look.

If you only want to know whether a quote's heat pump size is plausible, or which radiators are too small, draw the house in HeatLoss Pro for free, then press Calculate for €1.00: each room's heat loss, the radiators and the PDF report.

Engineering Accuracy

What the Calculation Does

New HeatLoss Pro projects follow EN 12831-1:2017, with the method MIS 3005-D sets out for the UK or DIN/TS 12831-1 for Germany, and the heat pump's output taken from its datasheet at your design temperature. It is not an MCS-approved tool: for MCS paperwork, use an MCS-approved calculator.

ΔT5 Hydronics & Low-Flow Scaling

Heat pumps run at a tight ΔT 5°C flow-return split (e.g. 45/40°C or 35/30°C) for maximum COP. Delivering heat with a 5°C delta requires ~3–4× higher water flow rates than a gas boiler, demanding properly sized large pipework. HeatLoss Pro sizes hydronic flow and rescales radiator catalogs for low water temps using BS EN 442 correction curves.

UFH Screed & Pipe Output

Model underfloor heating with precision: screed thickness, pipe center spacing (100mm, 150mm, 200mm), and floor coverings (tiles, wood, carpet with tog rating).

Temperature Sweep Curves

Interactive temperature curve sweep displays heat loss across the entire heating season from -15°C to +15°C to pinpoint the exact bivalent balance point.

Based on EN 12831

Room-by-room fabric loss, and ventilation from air changes or from MVHR with its heat recovery, following a simplified EN 12831 approach at the design outdoor temperature you set.

Direct Head-to-Head

Comprehensive Feature Matrix

Compare HeatLoss Pro directly with the four main alternative solutions on the market today.

Feature / Capability
HeatLoss Pro Winner
Heat Geek App Heatpunk (Midsummer) MCS Excel Sheets Enterprise CAD (MagiCAD)
Pricing & Value
Starting Price
Free Canvas • €1.00 / Report
£350 – £1,500+ (Course / network) "Free" (Equipment sales) Free / Cheap template €2,500 – €4,000 / year
Unlimited Monthly Pro
€29.99 / month (Cancel anytime)
Network fee (£40-£100+/mo) N/A (Tied to merchant) N/A €250+ / month / seat
Manufacturer Neutrality 100% Neutral (Any brand) Network tool Supplier tool Neutral (Manual input) Neutral
Data Privacy & Local Storage
Local Canvas Storage (Draw Safely Offline)
Works offline, syncs to your account. Calculations run on our server
Cloud-dependent (Projects on remote server) Cloud-dependent (Merchant servers) Local offline spreadsheet Local desktop file (Cloud license)
Workflow & Speed
Average House Calculation Time
3 to 5 minutes
20 to 30 minutes 30 to 45 minutes 60 to 90 minutes 2 to 4 hours
Ctrl+V Blueprint Paste & Tracing Direct Clipboard Paste No (Manual room dimensions) File upload required No (Manual tape measure) Complex DXF/DWG import
Live Real-time Math Feedback Instant 60 FPS update Step-by-step submission Page recalculate lag Spreadsheet recalculate Manual simulation run
Calculation Depth & Standards
Calculation method
Room-by-room, based on EN 12831 (simplified)
Yes Yes Yes (If formulas correct) Full Standard
Low-Temp Radiators & ΔT5 High-Flow Sizing Automatic exponent scaling Yes Yes Manual formula lookup Yes
Underfloor Heating Circuit Modeling Screed & Tog resistance Yes Yes Usually separate sheet Yes (Requires setup)
Temperature Sweep Curve Chart Interactive -15°C to +15°C Tabular views Static tables Manual chart creation Yes
Platform & Requirements
Installation Required
0 MB (100% In-Browser)
0 MB (Web) 0 MB (Web) Requires Microsoft Excel 5GB+ Heavy Windows Install
Device Compatibility
Mac, PC, iPad, Tablet, Phone
Browser / Mobile Desktop browser preferred Desktop with Excel Windows PC with GPU only
Instant PDF Client Reports Clean, One-Click Export Branded PDF Branded PDF Spreadsheet print Detailed CAD printout
Real Installer ROI

How Much Money & Time Will You Save?

Consider an active heating engineer or installer completing 40 residential heat pump surveys per year:

Annual Software Cost
€2,800+

Spent on enterprise CAD seat licenses or multiple subscription tools.

With HeatLoss Pro: €40.00 (pay-as-you-go) or €305.90/year unlimited.
Time Spent Sizing
60+ Hours

Wasted on manual data entry, dimension typing, and spreadsheet debugging.

With HeatLoss Pro: ~3.3 Hours total across 40 surveys (5 mins each).
Net Annual Benefit
+€2,760

Cash kept in your business plus 56+ hours returned to install pumps.

56 Hours Saved: Time to complete 2 extra paid heat pump installations!
Answers To Common Questions

Frequently Asked Questions

Which calculation method does HeatLoss Pro use? ↓
New projects use EN 12831-1:2017: transmission heat loss (\(\Phi_T = \sum A \times (U + \Delta U_{TB}) \times \Delta T\)) through walls, windows and roofs with an allowance for thermal bridges, floors on the ground by EN ISO 13370 to the yearly mean outdoor temperature, heat passed between rooms at different temperatures, and air (\(\Phi_V = 0.34 \times \dot V \times \Delta T\)) from the leakage of the house or each room's minimum fresh air, whichever is larger. The UK or German rules apply where they are chosen. Projects saved before then keep the simplified method (\(Q_V = 0.33 \times n \times V \times \Delta T\)). It's a design tool, not a certified calculation, and it isn't an MCS-approved calculator.
Does HeatLoss Pro work out cooling and overheating? ↓
Yes, for design. Each room's cooling load is worked out hour by hour over a design day (ASHRAE's daily range and clear sky, wall mass by EN ISO 13786), and the report's hot day runs every room together: the cooling you draw, the ground and the walls between rooms, and the windows of rooms nothing cools opened as CIBSE TM59 assumes. It is not a Part O or TM59 compliance assessment.
Can I paste blueprints directly from estate agents or PDFs? ↓
Yes! This is our flagship workflow feature. Simply use your operating system's screenshot tool (Windows Snipping Tool / Mac Shift+Cmd+4) to copy any floor plan from an architect drawing, EPC report, or estate agent brochure. Click on the HeatLoss Pro canvas and press Ctrl+V (or drag and drop the image file). Use our quick 2-point scale calibration to set the dimension, and trace rooms in seconds.
Is HeatLoss Pro tied to any specific heat pump brand or supplier? ↓
No. HeatLoss Pro is independent: no manufacturer, distributor or merchant funds it. The results come from the building physics alone, so you can select and install Vaillant, Daikin, Mitsubishi, Panasonic, Samsung, Grant, NIBE, or any other heat pump brand of your choice.
How does the €1.00 single payment work? ↓
Drawing rooms, tracing blueprints and exploring the demo house are free, with no account needed. When you press Calculate for your own house (the room-by-room heat loss, radiator adequacy checks and PDF print export), you unlock that specific project for just €1.00. If you do frequent jobs, the €29.99/month Pro subscription unlocks unlimited calculations across all projects.
Can I model multi-floor properties with underfloor heating and radiators? ↓
Yes. You can switch between Ground Floor, First Floor, and Loft tabs. Each room can have its own emitter configuration: underfloor heating with customized pipe spacing and floor finishes on the ground floor, and low-temperature heat pump radiators (45°C/40°C) or fan coils on upper floors.
Can an AI assistant draw the plan for me? ↓
Yes. HeatLoss Pro offers an AI assistant working in your browser tools to draw and fill in a plan from your drawings and product list: walls, windows, rooms, radiators, fan coils and the heat pump. It uses the same functions you do, every step can be undone, and it asks you before it replaces a drawing or calculates. The tools follow WebMCP, the W3C draft for a web page's own tools for AI, and are described for assistants in llms.txt. Draw a heat loss plan with an AI assistant
HeatLoss Pro Logo

Ready to Size Heat Pumps in 5 Minutes?

Join hundreds of modern HVAC engineers, heat pump installers, and energy assessors. No software download, no credit card required to start drawing.

Instant browser access • Save & share with unique links • €1.00 pay-as-you-go reports